Any Questions? Call Us:+8618695867837

315 kVA Cast Resin Dry Type Transformer Specs and Uses

Images
315 kVA Cast Resin Dry Type Transformer Specs and Uses
  • By ZTELEC GROUP
  • 2026-11-16

A 315 kVA cast resin dry type transformer is one of the most popular mid-size units in low-voltage power distribution. It is compact, safe for indoor installation and supplies enough capacity for most commercial buildings and small factories.

This guide explains the key specifications, losses, construction and typical uses of a 315 kVA dry-type transformer. It also shows how to choose the right configuration for your project.

315 kVA cast resin dry type transformer

What Is a 315 kVA Cast Resin Dry Type Transformer?

A dry-type transformer cools its core and windings with air instead of oil. A cast-resin transformer goes one step further. Its windings are encapsulated in vacuum-cast epoxy resin, which seals the coils against moisture, dust and contamination.

The 315 kVA rating sits in the standard R10 capacity series, between 250 kVA and 400 kVA. It is typically a step-down unit that converts medium voltage, such as 10 kV or 11 kV, to a low-voltage supply of 400 V or 415 V.

315 kVA Transformer Specifications

Exact data varies by manufacturer, standard and efficiency level. The table below shows typical values for a three-phase, 50 Hz unit built to IEC 60076-11 or GB/T 10228.

Parameter Typical Value
Rated capacity 315 kVA
Phases and frequency Three-phase, 50 Hz or 60 Hz
Primary voltage 6 kV, 6.6 kV, 10 kV, 11 kV, 13.8 kV or 20 kV
Secondary voltage 0.4 kV, 0.415 kV or 0.433 kV
Vector group Dyn11 (Yyn0 on request)
Impedance voltage 4%
Tap changer Off-circuit, ±2 × 2.5% or ±5%
Insulation class Class F (155 °C)
Temperature rise 100 K
Cooling method AN (natural air), AF optional
Fire and environment class F1, E2, C2
Enclosure IP20, IP21 or IP23
Sound level About 52 to 58 dB(A)
Approximate weight 1,100 to 1,500 kg

Rated Current at Common Voltages

Rated current helps you size cables, breakers and busbars. For a three-phase transformer, the current equals the kVA rating divided by root three times the line voltage.

On the high-voltage side, a 315 kVA unit draws about 18.2 A at 10 kV, 16.5 A at 11 kV and 27.6 A at 6.6 kV.

On the low-voltage side, the rated current is about 455 A at 400 V, 438 A at 415 V and 420 A at 433 V. Always size protective devices with margin for inrush current and future load growth.

Losses and Efficiency

No-Load and Load Losses

Losses are a major part of lifetime cost. No-load loss occurs whenever the transformer is energized, and load loss grows with the square of the current.

A modern 315 kVA cast resin transformer typically has a no-load loss of roughly 0.6 to 0.9 kW and a load loss of roughly 2.8 to 3.5 kW at 120 °C. Exact figures depend on core material and the efficiency grade you select.

Energy-Saving Options

Premium silicon steel cores and amorphous alloy cores reduce no-load loss significantly. Models such as the SCB13 and higher-efficiency series meet stricter energy standards.

For transformers that run around the clock, the lower loss design usually repays its extra cost within a few years.

Construction and Design Features

Core

The core is made from cold-rolled, grain-oriented silicon steel laminations with step-lap joints. This reduces noise, magnetizing current and no-load loss.

High-Voltage Winding

The high-voltage coil is wound from copper or aluminum conductor and cast in epoxy resin under vacuum. The result is a solid, void-free body with low partial discharge and strong resistance to short-circuit forces.

Low-Voltage Winding

The low-voltage coil is usually wound from foil, which balances ampere-turns and improves short-circuit strength. It is insulated with Class F or Class H material and cured for durability.

Protection and Monitoring

Most units include PT100 or PTC temperature sensors embedded in the low-voltage winding, connected to a digital temperature controller. The controller triggers fans, alarms and trip signals as temperatures rise.

Optional accessories include cooling fans, lightning arresters, anti-vibration pads, rollers and a metal enclosure with ventilation.

Advantages of a 315 kVA Cast Resin Transformer

Fire Safety

The epoxy resin is flame retardant and self-extinguishing. There is no flammable oil, so the transformer can be installed close to the load, even inside occupied buildings.

Moisture and Pollution Resistance

Encapsulated windings stay protected in humid, dusty or mildly corrosive air. This makes cast resin a strong choice for coastal sites, basements and tropical regions.

Low Maintenance

There is no oil to sample, filter or replace. Routine care is limited to cleaning, tightening connections and checking the temperature controller.

Compact and Eco-Friendly

The unit needs no oil pit or containment wall, which saves floor space and civil cost. The materials are recyclable and there is no risk of oil leakage.

cast-resin transformer

Typical Applications

Commercial and Public Buildings

A 315 kVA dry-type transformer fits shopping malls, offices, hotels, hospitals, schools and apartment towers. It supplies lighting, elevators, HVAC and general power safely near occupied areas.

Industrial Plants

Light and medium manufacturing sites use it to feed motors, production lines and compressors. Its resistance to dust and humidity suits workshops and processing plants.

Data Centers and IT Facilities

Low fire risk and stable performance make cast resin attractive for server rooms and telecom facilities. Units with a higher K-factor can handle harmonic-rich electronic loads.

Infrastructure and Transport

Metro stations, airports, tunnels and ports often require fire-safe equipment. A cast-resin transformer meets these demands and fits tight electrical rooms.

Renewable Energy and Utilities

Small solar plants, wind auxiliary systems and utility substations use 315 kVA units for station service and local distribution.

How to Select the Right 315 kVA Transformer

Confirm Voltage and Frequency

Match the primary voltage, secondary voltage and frequency to your grid. Specify tap ranges if your supply voltage fluctuates.

Check Load Profile

Calculate your peak load, power factor and growth plan. A 315 kVA transformer typically delivers about 250 kW at 0.8 power factor. Running at 60 to 80 percent load is often the most efficient range.

Consider Site Conditions

Review altitude, ambient temperature, humidity and ventilation. Above 1,000 m or in hot rooms, ask the manufacturer to apply derating or choose a higher insulation class.

Choose the Enclosure

An IP20 enclosure suits clean electrical rooms. Use IP21 or IP23 where dripping water or dust may be present, and add ventilation to maintain cooling.

Review Standards and Testing

Ask for compliance with IEC 60076-11, IEEE C57.12.01 or GB/T 10228. Request routine test reports, partial discharge data and, where needed, type test certificates.

315 kVA Transformer Price Factors

The price of a 315 kVA cast resin dry type transformer depends on conductor material, core grade, efficiency level and accessories. Copper windings cost more than aluminum but offer lower losses and higher strength.

Enclosure rating, temperature controller, fans and special certifications also affect the quotation. Compare total cost of ownership, including energy losses, rather than the purchase price alone.

Installation and Maintenance Tips

Install the transformer in a ventilated room with enough clearance around the coils. Keep air inlets clear and avoid placing heat sources nearby.

Before energizing, check insulation resistance, tighten all connections and verify the temperature controller settings. Inspect the unit once or twice a year and remove dust with dry compressed air or a soft brush.

Frequently Asked Questions

How many kW can a 315 kVA transformer supply?

At a power factor of 0.8, it supplies about 252 kW. At a power factor of 0.95, the output rises to nearly 300 kW.

Can a 315 kVA cast resin transformer be installed outdoors?

Yes, if it is fitted with a weatherproof enclosure such as IP54 or placed inside a compact substation. Standard IP20 units are for indoor use only.

What is the typical service life?

With proper loading and maintenance, a cast-resin transformer can operate for 25 to 30 years or longer.

The 315 kVA cast resin dry type transformer offers a strong balance of capacity, safety and low maintenance. It suits commercial, industrial and infrastructure projects where fire safety and reliability matter.

When you request a quotation, provide the voltage levels, frequency, vector group, impedance, enclosure rating and site conditions. A clear specification helps your supplier recommend the most efficient and cost-effective dry-type transformer for your project.

Prev:Reactive Power Compensation: How to Size a Capacitor Bank

Next:Back To List

  • Tags:
  • 315 kVA cast resin dry type transformer, 315 kVA transformer, dry-type transform

Leave A Comment