500kV Oil-Immersed Transformer Fault Analysis and Effective Solutions

Images
500kV Oil-Immersed Transformer Fault Analysis and Effective Solutions
  • By ZTELEC GROUP
  • 2025-09-27

500kV oil-immersed transformers are the cornerstone of ultra-high-voltage (UHV) power transmission systems. Their performance directly determines the reliability and stability of national power grids. However, due to continuous high-voltage operation and environmental influences, these transformers are prone to various faults. Understanding typical failure modes, diagnostic techniques, and effective solutions is critical for reducing risks, lowering maintenance costs, and extending service life.

500kV oil-immersed transformer

1. Typical Faults in 500kV Oil-Immersed Transformers

During long-term service, 500kV oil-immersed transformers face mechanical, electrical, and thermal stresses that can lead to multiple types of faults:

Insulation Deterioration

Paper insulation and transformer oil degrade over time due to heat, moisture, and oxidation. This results in reduced dielectric strength, higher partial discharge probability, and potential insulation breakdown.

Transformer Oil Leakage

Seal aging, loose fasteners, or welding cracks often cause oil leakage. In addition to oil level reduction, moisture and oxygen ingress accelerates insulation failure.

Overheating of Windings

Overload operation, blocked oil circulation, or radiator fouling can lead to excessive winding temperature. Prolonged overheating accelerates insulation aging and may deform windings.

Partial Discharge (PD)

PD usually occurs at insulation defects or sharp edges of conductors. If not controlled, localized discharges erode insulation layers and eventually cause catastrophic breakdown.

Core and Magnetic Circuit Issues

Common faults include loose core clamping, abnormal core grounding, and eddy current overheating. These increase losses and cause abnormal noise or vibration.

Bushing Failures

500kV bushings operate under extreme voltage stress. Oil leaks, internal cracks, or excessive dielectric loss factor may trigger explosions, posing high operational risks.

Tap Changer Malfunctions

On-load tap changers may experience contact wear, poor lubrication, or carbon deposit build-up. These lead to overheating, arcing, and sometimes internal fire.

2. Causes and Fault Diagnosis Methods

To ensure safe transformer operation, engineers use multiple diagnostic techniques:

Dissolved Gas Analysis (DGA)

DGA is the most reliable method for detecting faults. Gas levels such as hydrogen, methane, acetylene, and carbon monoxide indicate overheating, arcing, or insulation degradation.

Gas Chromatography

Gas chromatography provides detailed identification of thermal vs. electrical faults at different severity levels.

Infrared Thermography

Thermal imaging identifies overheating in bushings, windings, and cooling systems, preventing severe failures.

Partial Discharge Detection

UHF, acoustic, and ultrasonic sensors monitor partial discharge in real time, providing early warnings of insulation weakness.

Transformer Oil Quality Tests

Tests on moisture content, dielectric strength, and acidity reveal insulation performance and aging trends.

Electrical Testing

Insulation resistance, winding resistance, and dielectric loss measurements ensure electrical integrity.

transformer fault diagnosis

3. Practical Solutions for Transformer Faults

Insulation Improvement

Moisture removal, oil filtering, and oil replacement slow insulation aging. For severe cases, winding or insulation replacement is required.

Oil Leakage Repair

Leaks should be sealed using heat-resistant gaskets or precision welding. Preventive inspection reduces recurrence.

Cooling System Optimization

Cleaning radiators, checking pumps, and ensuring proper airflow help prevent overheating. Smart monitoring can adjust load distribution.

Partial Discharge Mitigation

Localized insulation defects should be repaired. Installing PD online monitoring ensures continuous safety tracking.

Core Fault Elimination

Loose laminations must be tightened, and abnormal grounding corrected. Damaged insulation requires replacement.

Bushing Replacement

Routine dielectric loss and capacitance tests allow early detection. Faulty bushings must be replaced immediately.

Tap Changer Maintenance

Regular inspection of contacts, insulating oil, and arc suppression chambers ensures reliable performance. Modern vacuum-type tap changers reduce failure risks.

4. Case Studies of Transformer Faults

Case Study 1: An abnormal temperature rise was detected in a 500kV transformer radiator. Infrared thermography identified blocked airflow. Cleaning restored normal operation.

Case Study 2: Elevated acetylene levels in DGA indicated arcing. Immediate shutdown prevented further insulation damage.

Case Study 3: Online partial discharge monitoring revealed internal defects in a bushing. Timely replacement avoided catastrophic explosion.

5. Preventive Maintenance Strategy

To maximize safety and reliability, companies should adopt condition-based and predictive maintenance strategies:

✔ Daily inspection of oil level, temperature, and noise
✔ Online monitoring of DGA, partial discharge, and thermal data
✔ Annual electrical testing and oil analysis
✔ Predictive maintenance using smart sensors and IoT
✔ Emergency response planning for sudden transformer failures

A 500kV oil-immersed transformer is a vital component of UHV power transmission. Typical faults such as insulation aging, oil leakage, overheating, and bushing failures can cause severe consequences if ignored. Advanced diagnostic techniques like DGA, infrared thermography, and partial discharge monitoring, combined with timely solutions and preventive strategies, can significantly extend transformer service life and ensure grid stability. For power utilities and industrial users, proactive maintenance is the key to safe and cost-effective operation.